Event IDs 5200 - 5299

Top  Previous  Next

Below are session related events from the ELM Enterprise Manager server or TNT Agent process.

Event Type:

I = Informational                W = Warning                E = Error

 

Event ID

Event Type

Message

5200

E3

Error opening configuration file: %1

5201

E

Fatal Error in %1 for stream %2

5202

E

Error connecting to database: %1

5203

E

Database access error %1

5204

E

Critical failure: failed loading configuration data from %1.%r

Contact TNT Support for assistance, or try these steps:%r

1. Move the above dat file to another folder.%r

2. Make a copy of %2.%r

3. Rename the copy to %3.%r

4. Start the ELM Server.

5205

E

The %1 service failed to initialize

5206

E

The service failed to initialize a session for %1. %2

5207

E

The service failed to initialize a session because the software license quota has been exceeded.

5208

E

Critical failure: failed storing configuration data to %1

5209

E

Critical failure: failed writing to registry. Check the registry permissions on the service account.

5210

E

The XML import feature is not available in evaluation mode.

5214

W1

A critical database failure occurred and the temporary database %1 has been enabled. Data in this temporary file will be merged with the configured database when it becomes available.

5215

E

A critical failure occurred while enabling fail-over to temporary database %1. This failure could result in loss of data.

5216

I1

The configured database has returned on-line. Temporary data written to %1 is now being merged with the database.

5217

I1

%1, recovery attempt completed for the database. %2

5218

I

%1 prune %2 %3 event records completed.

5219

E

%1, errors occurred attempting to purge event records. %2

5220

E

%1 %2 The Primary and Failover databases configured for ELM are not available. At least one of the configured databases needs to be available for the ELM Server service to start.

5221

I1

%1 The Primary database configured for ELM has returned on-line.

5222

E

Failed to drop the database %1. Error %2. Please make sure the SQL server is connectable.

5223

E

Error running database SQL script %1 %2

5225

W


 

Notes

The ELM Control panel applet has three Logging Levels, and these levels control how much detail is logged by the ELM Server. In general, event type determines which events are written at each level as detailed below:

Low - Log errors only.

Medium - Log errors and warnings.

High - Log errors, warnings and informational events.

Exceptions to this general scheme are indicated by the following superscripts:

1 This event is written at Low, Medium and High logging levels.

2 This event is written at Medium and High logging levels.

3 This event is written only at the High logging level.

4 Unclassified events are logged using this event ID. It is likely there will be error events and therefore written at Low, Medium, and High logging levels.

 

Please note that Actions defined in Monitor items are not affected by these logging levels and will always write events if defined.